This page contains instructions for the CDM GUI. In case of issue contact Darko Zaric. | This page contains instructions for the CDM GUI. In case of issue contact Darko Zaric. | ||
− | =GUI interface= | + | ==GUI interface== |
− | |||
{| align='center' | {| align='center' | ||
− | | [[ | + | | [[File:CDM_GUI_dzaric_v2.png|thumb|centre|1000px|CDM GUI appearance.]] |
|} | |} | ||
+ | |||
+ | Description of GUI parts: | ||
+ | Monitoring: Contains monitoring datapoint values. They are read-only. | ||
+ | Hood temperature: Displays temperature inside the hood. | ||
+ | Hood humidity: Displays humidity inside the hood. It should be below 80% to operate CDM. | ||
+ | Camera temperature status: If the CDM camera is connected it will display it's temperature status. It should be Normal. If it displays Warning or Critical, disconnect the CDM camera and contact Darko. | ||
+ | Status: This part displays information about the system status. This part is still unfinished, so it mostly displays No status. | ||
+ | FSM state: Display the current Finite State Machine state the CDM is in. | ||
+ | FSM transition: Displays if the system is in transition from one FSM state to another. If it is 1 then it is in transition and won't be able to receive FSM commands. If 0, then you can provide the available FSM commands. | ||
+ | Circle x: Current circle center in horizontal direction, units in arcsec. | ||
+ | OARL 1 x: Current OARL 1 center in horizontal direction, units in arcsec. | ||
+ | OARL 2 x: Current OARL 2 center in horizontal direction, units in arcsec. | ||
+ | |||
+ | Configuration: Contains configuration datapoint values. You can read the current values and input new values to be provided to the Configure commands. | ||
+ | Exposure time: |
Revision as of 14:21, 10 March 2021
This page contains instructions for the CDM GUI. In case of issue contact Darko Zaric.
GUI interface
Description of GUI parts: Monitoring: Contains monitoring datapoint values. They are read-only. Hood temperature: Displays temperature inside the hood. Hood humidity: Displays humidity inside the hood. It should be below 80% to operate CDM. Camera temperature status: If the CDM camera is connected it will display it's temperature status. It should be Normal. If it displays Warning or Critical, disconnect the CDM camera and contact Darko. Status: This part displays information about the system status. This part is still unfinished, so it mostly displays No status. FSM state: Display the current Finite State Machine state the CDM is in. FSM transition: Displays if the system is in transition from one FSM state to another. If it is 1 then it is in transition and won't be able to receive FSM commands. If 0, then you can provide the available FSM commands. Circle x: Current circle center in horizontal direction, units in arcsec. OARL 1 x: Current OARL 1 center in horizontal direction, units in arcsec. OARL 2 x: Current OARL 2 center in horizontal direction, units in arcsec.
Configuration: Contains configuration datapoint values. You can read the current values and input new values to be provided to the Configure commands. Exposure time: