Difference between revisions of "PMT vs magnetic field paper"
(Created page with "'''Back to Main page''' <br> '''Back to Camera paper page''' <br> == People involved == * Y. Kobayashi * D. Tateishi * Y. Sunada * T. Saito...") |
|||
Line 1: | Line 1: | ||
'''Back to [[Main_Page|Main page]]''' <br> | '''Back to [[Main_Page|Main page]]''' <br> | ||
'''Back to [[Camera_Papers|Camera paper page]]''' <br> | '''Back to [[Camera_Papers|Camera paper page]]''' <br> | ||
+ | |||
+ | == Outline of the project == | ||
+ | |||
+ | * Purpose: Evaluation and understanding of effect of magnetic field on the PMTs of CTA LST-1 | ||
+ | * Onsite test | ||
+ | ::- Effect of geomagnetic field was examined by calibrating the camera at different pointing directions. | ||
+ | ::- 0.5% change in PMT gain depending on x-component of geomagnetic field was seen | ||
+ | ::- No problem in terms of the telescope performance | ||
+ | * Investigation at lab | ||
+ | ::- In order to confirm that the result of the onsite test can be explained by the geomagnetic field, measurement is performed at lab. | ||
+ | ::- Multi p.e. signal shows small dependence even with weak magnetic field close to geomagnetic field. | ||
+ | ::- Single p.e. signal indicates positive correlation between gain and magnetic field, which is qualitatively consistent with the LST-1 result. | ||
+ | ::- Results obtained with the F-factor method indicates the dependence seen in the onsite test is indeed likely to be due to effects of the geomagnetic field. | ||
== People involved == | == People involved == |
Latest revision as of 08:51, 14 April 2022
Back to Main page
Back to Camera paper page
Contents
Outline of the project[edit]
- Purpose: Evaluation and understanding of effect of magnetic field on the PMTs of CTA LST-1
- Onsite test
- - Effect of geomagnetic field was examined by calibrating the camera at different pointing directions.
- - 0.5% change in PMT gain depending on x-component of geomagnetic field was seen
- - No problem in terms of the telescope performance
- Investigation at lab
- - In order to confirm that the result of the onsite test can be explained by the geomagnetic field, measurement is performed at lab.
- - Multi p.e. signal shows small dependence even with weak magnetic field close to geomagnetic field.
- - Single p.e. signal indicates positive correlation between gain and magnetic field, which is qualitatively consistent with the LST-1 result.
- - Results obtained with the F-factor method indicates the dependence seen in the onsite test is indeed likely to be due to effects of the geomagnetic field.
People involved[edit]
- Y. Kobayashi
- D. Tateishi
- Y. Sunada
- T. Saito
Index and contents[edit]
- Introduction
- The onsite test
- - Introduction to the LST-1 camera
- - Method
- - Results
- - Discussion
- Measurement at laboratory
- - Measurement setup
- - Calibration of the Magnetic field
- - Data acquisition and analysis
- - Results
- - Discussion
- Discussion