| 2019-01-23 || One of the four Elevation breaks is stuck during drive tests by LAPP || To Repair (MPI/CaSana)  || C-Lock Washer of the shaft fell into the disks. The break had to be removed and C-Lock Washer put back. Repaired by CaSana on 25.1.2019 || [[File:Break 1.jpg|140px|thumb|left|Break ring]] [[File:Break cylinder.jpg|140px|thumb|right|Break cylinder]] [[File:Break cover.jpg|150px|thumb|center|Break cover]] || yes
+
| 2019-01-23 || One of the four Elevation breaks is stuck during drive tests by LAPP || To Repair (MPI/CaSana)  || C-Lock Washer of the shaft fell into the disks. The break had to be removed and C-Lock Washer put back. Repaired by CaSana on 25.1.2019 || [[File:Break 1.jpg|140px|thumb|left|C-Lock Washer]] [[File:Break cylinder.jpg|140px|thumb|right|Break cylinder]] [[File:Break cover.jpg|150px|thumb|center|]] || yes
  
 
|- valign="top"
 
|- valign="top"
 
| 2019-01-22 || Water in electrical boxes of the ALS || Dried boxes, called Ayumar  || need to replace the boxes  || [[File:IMG 20190122 121250.jpg|250px|thumb|center|ALS box]]  || no
 
| 2019-01-22 || Water in electrical boxes of the ALS || Dried boxes, called Ayumar  || need to replace the boxes  || [[File:IMG 20190122 121250.jpg|250px|thumb|center|ALS box]]  || no

Revision as of 08:42, 29 January 2019

Enter comments in reverse time order

Date What happened? Corrective measures Comments Documents Incident Closed?
2019-01-23 One of the four Elevation breaks is stuck during drive tests by LAPP To Repair (MPI/CaSana) C-Lock Washer of the shaft fell into the disks. The break had to be removed and C-Lock Washer put back. Repaired by CaSana on 25.1.2019
C-Lock Washer
Break cylinder
Break cover.jpg
yes
2019-01-22 Water in electrical boxes of the ALS Dried boxes, called Ayumar need to replace the boxes
ALS box
no