Difference between revisions of "Logbook IFplate-Assembly-Mirca-JanFeb2018"

From my_wiki
Jump to: navigation, search
(Enter comments in reverse time order)
Line 7: Line 7:
 
| 2018-01-10 || Satoshi, Tomohiro || arrival in La Palma || ||
 
| 2018-01-10 || Satoshi, Tomohiro || arrival in La Palma || ||
 
|-
 
|-
| 2018-01-11 || Martin, Satoshi, Tomohiro || preparation for IF plate assembly || We removed 351 unnecessary aluminum plates and 700 small pins to be threaded. We also confirmed how to assemble IF plates and finished 2 plates additionally (in total 9). ||
+
| 2018-01-11 || Martin, Satoshi, Tomohiro || preparation for IF plate assembly || We removed 351 unnecessary aluminum plates and 700 small pins to be threaded. We also confirmed how to assemble IF plates and completed 2 plates additionally (in total 9). ||
 
|-
 
|-
| 2018-01-12 || Martin, Satoshi, Tomohiro || IF plate assembly ||  We finished 11 plates (in total 20) and finished. Besides we attached tube spacers for 10 plates.||
+
| 2018-01-12 || Martin, Satoshi, Tomohiro || IF plate assembly ||  We completed 11 plates (in total 20) and finished. Besides we finished tube spacers for 10 plates.||
 
|-
 
|-
 
|}
 
|}
  
 
== Trouble Shooting ==
 
== Trouble Shooting ==
Under construction.
+
 
  
 
== Tips ==
 
== Tips ==
Under construction.
+
- Some of actuators have watertight belts so far from their tops that IF plates cannot be adjusted to the right positions vertically.¥¥
 +
We found only one (with 2 mm displacement) out of 20 so far.
 +
- Bolts for fixing tube spacers have square shapes under their hats. Some of the square shapes are tight and difficult to slide smoothly. We might not use them.

Revision as of 17:06, 14 January 2018

Enter comments in reverse time order

Date Who did it? Action Comments Documents
2018-01-10 Satoshi, Tomohiro arrival in La Palma
2018-01-11 Martin, Satoshi, Tomohiro preparation for IF plate assembly We removed 351 unnecessary aluminum plates and 700 small pins to be threaded. We also confirmed how to assemble IF plates and completed 2 plates additionally (in total 9).
2018-01-12 Martin, Satoshi, Tomohiro IF plate assembly We completed 11 plates (in total 20) and finished. Besides we finished tube spacers for 10 plates.

Trouble Shooting

Tips

- Some of actuators have watertight belts so far from their tops that IF plates cannot be adjusted to the right positions vertically.¥¥ We found only one (with 2 mm displacement) out of 20 so far. - Bolts for fixing tube spacers have square shapes under their hats. Some of the square shapes are tight and difficult to slide smoothly. We might not use them.