- Some of actuators have watertight belts so far from their tops that IF plates cannot be adjusted to the right positions vertically.
 
- Some of actuators have watertight belts so far from their tops that IF plates cannot be adjusted to the right positions vertically.
We found only one (with 2 mm displacement) out of 20 so far.
+
We found 3 with ~5 mm displacement out of 34 so far. We may have to replace the belts with new ones (Martin said there are belts fixing with screwing here in La Palma.)
  
 
- Bolts for fixing tube spacers have square shapes under their hats. Some of the square shapes are tight and difficult to slide smoothly. We might not use them.
 
- Bolts for fixing tube spacers have square shapes under their hats. Some of the square shapes are tight and difficult to slide smoothly. We might not use them.

Revision as of 22:03, 19 January 2018

Enter comments in reverse time order

Date Who did it? Action Comments Documents
2018-01-18 Martin, Satoshi, Tomohiro IF plate assembly We finished attaching tube spacers on 30 plates. (in total 20 completed & 160 tube spacer attached) We stopped attaching them as the total number reached 180, enough for ordinary IF plates.
2018-01-17 Martin, Satoshi, Tomohiro IF plate assembly We finished attaching tube spacers on 30 plates. (in total 20 completed & 130 tube spacer attached) Eduardo brought 150 threaded pins to Mirca.
2018-01-16 Martin, Satoshi, Tomohiro IF plate assembly We finished attaching tube spacers on 35 plates. (in total 20 completed & 100 tube spacer attached)
2018-01-15 Martin, Satoshi, Tomohiro IF plate assembly We finished attaching tube spacers on 36 plates. (in total 20 completed & 65 tube spacer attached)
2018-01-14 Satoshi, Tomohiro IF plate assembly We finished attaching tube spacers on 19 plates. (in total 20 completed & 29 tube spacer attached)
2018-01-12 Martin, Satoshi, Tomohiro IF plate assembly We completed 11 plates and finished attaching tube spacers on 10 plates. (in total 20 completed & 10 tube spacer attached)
2018-01-11 Martin, Satoshi, Tomohiro preparation for IF plate assembly We removed 351 unnecessary aluminum plates from actuators and 700 small pins to be threaded. We also confirmed how to assemble IF plates and completed 2 plates additionally (in total 9 completed).
2018-01-10 Satoshi, Tomohiro arrival in La Palma

Trouble Shooting

Tips

- Some of actuators have watertight belts so far from their tops that IF plates cannot be adjusted to the right positions vertically. We found 3 with ~5 mm displacement out of 34 so far. We may have to replace the belts with new ones (Martin said there are belts fixing with screwing here in La Palma.)