Logbook IFplate-Assembly-Mirca-JanFeb2018
Enter comments in reverse time order
Date | Who did it? | Action | Comments | Documents |
---|---|---|---|---|
2018-02-07 | Satoshi, Tomohiro | IF plate assembly | We attached LOCTITE on 85 IF plates. (in total 180 plates) We started to remove unnecessary tube spacers for some IF plates close to the dish edge, according to Robert's drawing. | |
2018-02-06 | Satoshi, Tomohiro | IF plate assembly | We attached LOCTITE on 95 IF plates. (in total 100 plates) | |
2018-02-05 | Satoshi | CMOS camera assembly | For 5 plates I attached LOCTITE to the nuts to fix fixed-point milling parts & small gaps between the milling parts and two big plates. It measured ~7 min/plate by one person. | |
2018-02-01 | Masahiro, Daniel, Satoshi, Tomohiro | attachment of actuator caps and some discussions | We bought gris for O-ring of actuator tops. We discussed the preparation of AMC box installation and CMOS camera installation. | |
2018-01-31 | Masahiro, Daniel, Satoshi, Tomohiro | unpacking shipments and some discussions | We unpacked deliveries from ICRR. They include actuator caps to attach to IF plates. We made discussions about LOCTITE for the fixed-point nuts of IF plates, the number of screws of actuator caps or CMOS holders, and so on. | |
2018-01-30 | Satoshi | CMOS camera settings | I prepared for setups of CMOS cameras and finished 56 cameras. | |
2018-01-29 | Satoshi | CMOS camera settings | I fixed the measures of iris and focus of the CMOS lens with orange LED 28 m away. I installed a software of IP address configuration for the cameras and tried with some cameras. | |
2018-01-26 | Martin, Satoshi | IF plate assembly | We replaced wrong-positioned watertight belts with new ones and adjusted vertically the actuators which have >5 mm error (in total 8). We did the same adjustment to the actuators whose watertight belts were slipped off by mistake (in total 3). | |
2018-01-25 | Martin, Satoshi | IF plate assembly | We tried to replace watertight belts of actuators with new ones from MAGIC experiment. Satoshi broke a new one while screwing. We learned how strongly we fix the belts. | |
2018-01-24 | Koji, Satoshi, Tomohiro | IF plate labeling | We attached coordinate-labels on all the completed plates. | |
2018-01-23 | Martin, Koji, Satoshi, Tomohiro | IF plate assembly | We finished attaching actuators to 42 plates. (in total 180 completed). We finished all the ordinary IF plates except the ones on edges. | |
2018-01-22 | Martin, Koji, Satoshi, Tomohiro | IF plate assembly | We finished attaching actuators to 86 plates. (in total 138 completed). | |
2018-01-21 | Koji, Satoshi, Tomohiro | IF plate assembly | We finished attaching actuators to 18 plates. (in total 52 completed) We stored completed IF plates so that their positions correspond to the ones in the dish structure of the telescope. | |
2018-01-19 | Martin, Satoshi, Tomohiro | IF plate assembly | We confirmed how to adjust fixed points horizontally (with a caliper Martin bought today). We finished attaching actuators to 14 plates. (in total 34 completed) We cannot fix actuator covers as they have not arrived in Mirca yet. We also received all the threaded 700 pins we ordered last week. | |
2018-01-18 | Martin, Satoshi, Tomohiro | IF plate assembly | We finished attaching tube spacers on 30 plates. (in total 20 completed & 160 tube spacer attached) We stopped attaching them as the total number reached 180, enough for ordinary IF plates. | |
2018-01-17 | Martin, Satoshi, Tomohiro | IF plate assembly | We finished attaching tube spacers on 30 plates. (in total 20 completed & 130 tube spacer attached) Eduardo brought 150 threaded pins to Mirca. | |
2018-01-16 | Martin, Satoshi, Tomohiro | IF plate assembly | We finished attaching tube spacers on 35 plates. (in total 20 completed & 100 tube spacer attached) | |
2018-01-15 | Martin, Satoshi, Tomohiro | IF plate assembly | We finished attaching tube spacers on 36 plates. (in total 20 completed & 65 tube spacer attached) | |
2018-01-14 | Satoshi, Tomohiro | IF plate assembly | We finished attaching tube spacers on 19 plates. (in total 20 completed & 29 tube spacer attached) | |
2018-01-12 | Martin, Satoshi, Tomohiro | IF plate assembly | We completed 11 plates and finished attaching tube spacers on 10 plates. (in total 20 completed & 10 tube spacer attached) | |
2018-01-11 | Martin, Satoshi, Tomohiro | preparation for IF plate assembly | We removed 351 unnecessary aluminum plates from actuators and 700 small pins to be threaded. We also confirmed how to assemble IF plates and completed 2 plates additionally (in total 9 completed). | |
2018-01-10 | Satoshi, Tomohiro | arrival in La Palma |
Trouble Shooting
- Some of actuators have watertight belts so far from their tops that IF plates cannot be adjusted to the right positions vertically. We found ~10 with ~5 mm displacement out of 180. We replaced the belts with new ones (Martin brought ones used for MAGIC).
- We put strong force and slipped off 2-3 watertight belts by mistake while adjusting actuators vertically. We also replaced them with new ones.
- 2018/02/06 : Beforehand Daniel took one IF plate by car to Roque and came back, and that plate had a threaded cylinder pin loosened. We have to specify if the loosening may come from vibration of the car or just forgetting tightening. We checked loosening of the pins for other plates and found one with 1 missing pin out of 100 plates.
Tips
adjusting fixed points and actuators horizontally :
- When milling parts cannot move smoothly, you may have to loosen bolts fixing pentagonal spacers inside.
- We adjusted horizontal positions of fixed points with tail of a caliper.
adjusting actuator positions vertically :
- We adjusted vertical positions of actuators with a simple tool below.
- In case a watertight belt interferes, and 3-4 mm is enough to shift actuators farther, it is enough to cut the rubber sticking out.