Logbook Optics-Setup-Mirca-Apr2018

From my_wiki
Revision as of 21:15, 8 April 2018 by Satoshifukami (talk | contribs) (Trouble Shooting)
Jump to: navigation, search

Enter comments in reverse time order

Date Who did it? Action Comments Documents
2018-04-08 Koji, Satoshi CMOS camera setup We put loctite on screws of the lens mount for all the 198 cameras. Then we started attaching CMOS holders and finished ~100. We also made a setup for CMOS angle adjustment.
2018-04-07 Satoshi CMOS camera setup I finished labeling, adjusting lens, IP configuration and IP address table for 198 CMOS cameras.
2018-04-06 Satoshi arrival in La Palma

Trouble Shooting

2018/04/07

We had one camera (1/198) which could not be connected from AMC PC.

Tips

2018/04/07

- When adjusting lens, we put loctite on pins for focus, but not for pins for iris.

2018/04/08

- CMOS camera shields are very tight. We cannot screw some of them completely. In that case you can make use of a CMOS holder to fix them tightly.

- Put loctite on screws of lens mount slowly otherwise loctite can be sticked on the lenses or CMOS sensors.