Module exchange
Date clusco module ID Module IP old ID new ID issue elog
20220511 110 10.1.5.22 1-21 2-48 Suprious trigger rate without HV elog
20220511 226 10.1.6.134 1-101 2-135 Fuse Blown elog
20210831 47 10.1.5.132 1-135 PLL lock of the 3rd DRS4 in the Dragon elog
20210831 123 10.1.5.35 2-136 Impossible to apply HV and too high anode current even with 250 V elog
20210302 15 10.1.6.16 2-48 Anode current is too low, no calib pulse []
20210302 110 10.1.5.22 1-148 Pulse was sometimes not in the window. Offset is lower sometimes. The third line of DRS have some problems []
20210302 155 10.1.7.150 1-11 could not power up this module elog
20191001 27 10.1.6.28 1-1 hard to power on []
20191001 102 10.1.5.14 2-39 broken PMT []
20191001 244 10.1.6.152 2-39 unusable DRS offset []
20191001 119 10.1.5.31 1-34 unlocked PLL []



PMT HV table (EDMS: https://edms.cern.ch/ui/#!master/navigator/document?P:100649165:100710000:subDocs)
Date from which run produced using runXXX elog
20200813
202102XX 3513 (20210215)
202103XX 3891 (20210303)
202203XX 7440 (20220323)
20220524 8410 (20220522) [1]
20220527 8485- 8472 (20220526) [2]


DRS4 pedestal file for online baseline correction
Date from which run pedestal run elog
20220527 8480 - XXX [3]