Fast Analysis PKS1725 ToO Feb Mar 2024 P062
Contents
Fast analysis PKS1725 ToO P062 (March 2024)
General information
- Name of the source: PKS1725+123
- Brief description of the source:
- Object type : FSRQ
- Redshift (z) : 0.58
- Other relevant information: Observations triggered because Seiya's Fermi-LAT analysis found 2 HE photons (>7 GeV) from PKS 1725+123. The latest 3-days SED also has a hard index (1.69).
- RA: 17 28 00.5 (hh mm ss), Dec: +12 17 20.4 (dd mm ss)
- RA, Dec in deg (ICRS): 262.02938006, 12.26096821
- Analysis by:
- Daniel Morcuende (IAA-CSIC - dmorcuende@iaa.es)
Data-taking information
- Dates of data-taking:
- Date (time of observation h): 2024-03-16 (0.9 h livetime)
- ZD range (deg): 20 - 35 deg
- AZ range (deg): 110 - 130 deg
- Runs:
- Date (time of observation h): 2024-03-16 (0.9 h livetime)
'2024-03-16': [17183, 17184, 17185, 17186]
- Joint observations with MAGIC? : No
General analysis information
- source-independent analysis
- lstchain v0.10.7
Monte Carlo information
- All-sky MC production used: 20240131_allsky_v0.10.5_all_dec_base
- Declination line (training): dec_2276
DL1 data
LSTOSA standard production (v0.10/tailcut84) of DL1b run-wise merged files.
/fefs/aswg/data/real/DL1/YYYYMMDD/v0.10/tailcut84/dl1_LST-1.Run?????.h5
Random forest
Source declination is 12.3 deg. Two closest MC declination tracks are 9 and
/fefs/aswg/data/models/AllSky/20240131_allsky_v0.10.5_all_dec_base/dec_2276
DL2 data
Config file:
Files in:
/fefs/aswg/workspace/daniel.morcuende/data/real/DL2/PKS1725/dec_2276
DL3 data & IRF
"EventSelector": { "filters": { "intensity": [50, Infinity], "width": [0, Infinity], "length": [0, Infinity], "r": [0, 1], "wl": [0.01, 1], "leakage_intensity_width_2": [0, 1], "event_type": [32, 32] } }, "DL3Cuts": { "min_event_p_en_bin": 100, "min_gh_cut": 0.1, "max_gh_cut": 0.95, "min_theta_cut": 0.0, "max_theta_cut": 0.2, "fill_theta_cut": 0.2, "allowed_tels": [1] },
- 70 % efficiency for both gammaness and theta gamma-ray selection cuts
- Point-like IRF
High-level analysis
- Gammapy 1.1
- 1D analysis (point-like IRF)
Analysis Results
Theta2 plot
Settings:
- Theta2 cut: 0.04 deg2 for signal extraction
- normalization range 0.1 - 0.4 deg2
- 3 off positions
- Energy range 10 - 1000 GeV
- 2024-03-16